Equipment
Step 1/15 ·0 inspected

RL Rotary Valve

About this equipment

The RL Rotary Valve is the switching valve assembly on a regenerative thermal oxidizer (RTO) that alternates process gas flow between A-side and B-side media beds. It includes a driven gear, drive plate, lift cylinder, seal plate, and main seal ring, with measured valve gaps across cylinder positions A2–A26 and B2–B26 used as the primary health metric.

#1 · Valve Gap

Measure valve gap at A2–A26 and B2–B26

Valve gap clearance is the primary health indicator for the rotary valve; loss of gap leads to seal damage and process leakage between A and B sides.

Focus: Record clearance at each numbered position on both A and B cylinders; expected range is approximately .010–.015 inches. Flag any zero readings as HIGH severity.
Severity signals (4)
  • all positions zero clearance → HIGH
  • some positions at 0 with others normal → LOW–MEDIUM
  • measurements obstructed by buildup → MEDIUM
  • all positions within .010–.015 in → NONE
No photos yet — use the action bar below.