May 13, 2026, 8:33:17 PM · 16110ms · 6851 tokens · card #2
Overall severity
LOW
— Summary

Overall exterior view of CleanSwitch RTO appears structurally intact, but technician reports a new rumble during damper switchovers and fresh light-tan dust accumulating around the lower inlet duct flange — suggesting a developing duct leak or seal degradation not fully resolvable from the photo alone.

— Recommended action

Inspect inlet duct flange and gasket for leakage; check internal damper hardware/seals for looseness during switchover; sample dust to determine if it is process residue or ceramic media fines.

— Observations (4)
NONE
Unit exterior, access platform, ladder, and control enclosure are in place with no visible structural damage or corrosion.
confidence 90%
LOW
Inlet ductwork emits a new audible rumble during damper switchovers per technician — consistent with loosened internal damper hardware, gasket flutter, or developing duct flange leak.
confidence 70%
LOW
Fresh light-tan dust accumulation reported around lower duct flange indicates probable flange/gasket leakage of process exhaust or media fines escaping past a seal.
confidence 75%
NONE
No leak plume, panel damage, or insulation loss visually evident in the photo; defect signature is primarily acoustic and particulate.
confidence 80%
— Classification
part
complete unit with ductwork and access platform
type
regenerative thermal oxidizer
view
exterior side view
family
air pollution control
reason
Large gray industrial enclosure with overhead exhaust ducting, gas piping manifolds, and access platform/ladder typical of an RTO (regenerative thermal oxidizer) installation outside a facility.
source
context
confidence
0.8
taxonomy_type_id
null
taxonomy_family_id
null
— Retrieved examples
#1972#1797#1985#1732#1987

Top-K examples from the knowledge corpus used as visual context for this inspection.

— Metadata
image_uri
s3://luthier-assets/inspections/1/220d2bab-9685-41fe-b34c-37c9d6b4a0db-0004-eb9404a9f972743c.png
model_version
claude-opus-4-7
prompt_template
inspect-v2
tokens (in/out)
5779 / 1072
cache (creation/read)
0 / 0
latency
16110 ms
© Industria Machina · Demonstration prepared for Dürr
System health: 99.8% Nominal