← Back to all inspections
— Inspection #17

regenerative thermal oxidizer

May 13, 2026, 8:26:10 PM · 16932ms · 6819 tokens · card #2
Overall severity
LOW
— Summary

Overall exterior view of CleanSwitch RTO unit appears structurally intact with ladder, platform, ductwork, and control enclosure in place; however, technician reports intermittent rumbling from inlet ductwork during damper transitions and new light-tan dust accumulation, suggesting possible internal media degradation or duct/damper issue not visible externally.

— Recommended action

Schedule internal inspection of inlet ductwork, switching/tee dampers, and media beds; check damper actuator timing, seal integrity, and sample dust for ceramic fines.

— Observations (3)
NONE
Unit exterior, ductwork, access platform, ladder, and control enclosure are visually intact with no obvious corrosion, panel damage, or external leakage.
confidence 90%
LOW
Technician reports intermittent rumbling from inlet ductwork during damper transitions — symptom consistent with damper slamming, loose internal hardware, or ceramic media fines migration.
confidence 75%
LOW
New light-tan dust accumulation in inlet duct area reported by crew suggests possible ceramic media fines escaping bed or duct/seal leakage upstream of media.
confidence 70%
— Classification
part
main unit with ductwork and access platform
type
regenerative thermal oxidizer
view
exterior outdoor installation
family
air pollution control
reason
Large skid-mounted gray industrial enclosure with overhead exhaust ductwork, gas piping, and access ladder/platform branded 'CleanSwitch' is characteristic of an RTO (regenerative thermal oxidizer) installation.
source
context
confidence
0.78
taxonomy_type_id
null
taxonomy_family_id
null
— Retrieved examples
#1972#1797#1985#1732#1987

Top-K examples from the knowledge corpus used as visual context for this inspection.

— Metadata
image_uri
s3://luthier-assets/inspections/1/405eabef-5316-4a9f-bb34-a93ec70030da-0004-eb9404a9f972743c.png
model_version
claude-opus-4-7
prompt_template
inspect-v2
tokens (in/out)
5784 / 1035
cache (creation/read)
0 / 0
latency
16932 ms
© Industria Machina · Demonstration prepared for Dürr